The cause and solution of the failure of the exhaust pressure not reaching the predetermined pressure

1. The gas output of the air compressor is less than the actual gas consumption. The connected equipment and pipe network should be checked, and any leaks should be repaired in time. If the actual air consumption is greater than the air output of the air compressor under normal operating conditions, the air compressor with a larger size should be replaced or the air compressor unit should be added.

3. The air filter element is dirty and clogged, resulting in insufficient air intake and low exhaust pressure of the air compressor unit. Check air filter condition and replace if necessary.
4. Solenoid valve failure. The main bleed solenoid valve and the cold start bleed solenoid valve on the exhaust line are leaking and need to be replaced.
5. Control the leakage of the air hose, and replace the hose that controls the air.
6. The intake valve is insensitive or not fully opened. Overhaul and check the condition of the control system.

8.The safety valve leaks, and the valve needs to be recalibrated or replaced.